60–200 mmCam-lockCeiling / roof
Cam-lock ceiling / roof panel
- PUF core
- Cam-lock
Transport extraFlashing as per requirement
All panels9 panel types
By application7 uses
CalculatorArea, count, BOQ
Thickness guideU-values
Unit converterft ↔ m, sq ft ↔ m²
BrandsCompare in one quote
Dispatch cities20 cities
GuidesPrice, thickness, PIRTransport extraFlashing as per your requirement

Made in batch (discontinuous) presses with eccentric cam-lock hooks foamed into the edges. Turn a hex key and two panels pull tight against each other: a quick, airtight joint for cold rooms, freezers, ripening and pharma rooms.
Transport extra, quoted separately for your pincodeFlashing as per your requirement
Made in batch (discontinuous) presses with eccentric cam-lock hooks foamed into the edges. Turn a hex key and two panels pull tight against each other: a quick, airtight joint for cold rooms, freezers, ripening and pharma rooms.



Locks pull the panels together. You need fewer site sealant beads and fewer cold bridges at the joint.
Unlock and re-erect. Useful when a cold room may be moved or extended later.
Commonly 60–200 mm, so the same system covers +15 °C rooms through −40 °C blast freezers.
Photos are representative stock images (see credits), not our projects.
Typical ranges; they vary by brand. Exact values for your order are stated in the quote and on the maker’s datasheet.
We do not auto-count flashing. Tell us the profile, girth, length and colour of each trim and it is made to match your panels.
Metres = Feet × 0.3048
12 ft × 0.3048 = 3.658 m
1 ft = 0.3048 m (exact)
Calculated for the core with k ≈ 0.022 W/mK. Lower U means less heat gets through. U = 1 / (0.13 + d/k + 0.04).
The core only. Joints, fixings and doors add heat gain in a real room. Which thickness for which temperature?
Bar length = heat let through, relative to 60 mm. Figures in W/m²K.
Typical values; the quote and the maker’s datasheet state the figures for your order.
Commonly 60, 80, 100, 120, 150, 200 mm (typical; varies by brand). Cam-lock panels are made in batch presses, which suits thick cores.
About 0.178 W/m²K, calculated for the core with k ≈ 0.022 W/m·K: U = 1 / (0.13 + d/k + 0.04). Joints, fixings and doors add heat gain in a real building.
Core density 38–42 kg/m³ (typical; varies by brand). Skins: Coated steel 0.4–0.6 mm both faces (typical). Cover width 1000–1200 mm cover width (1000 / 1150 mm common).
Standard PUF is combustible. Ask for the brand’s FR-grade foam or PIR, and for the test certificate.
The panel rate depends on thickness, skin gauge and coating, core, brand and quantity, so we quote today’s rate per brand for your specification. Transport is extra and quoted separately for your pincode; flashing is made as per your requirement.
Walls and ceilings of cold rooms; Freezers and blast freezers; Ripening chambers; Pharma cold stores.
60–200 mmCam-lockCeiling / roof
Transport extraFlashing as per requirement
60–150 mm
30–150 mmContinuousWall
Transport extraFlashing as per requirement
EnquiryRates move with steel and chemical prices, so we quote fresh every time, with every available brand on one sheet. Transport is extra and quoted separately.